Search results for "frequency analysi"
showing 10 items of 116 documents
Recent advances in paleoflood hydrology: From new archives to data compilation and analysis
2018
8 pags, 4 figs
In vitro comparison of primary stability of two implant designs in D3 bone
2016
Background Primary stability (PS) is a key factor for implant survival rate and depends on implant design or bone quality. The aim of this study was to compare different thread designs implants, evaluating PS with periotest values (PV) and implant stability quotient (ISQ) values through resonance frequency analysis (RFA). Material and Methods A total of 60 implants (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in freshly bovine ribs in vitro. Two designs were used: 30 tapered body with single thread design (PHI) and 30 tapered body with double thread design implants (PHIA). Both designs were 4mm wide and 12mm long. Implants were placed according to manufacturer’s guidelines.…
2017
Functional near infrared spectroscopy (fNIRS) is a promising neuroimaging method for investigating networks of cortical regions over time. We propose a directed effective connectivity method (TPDC) allowing the capture of both time and frequency evolution of the brain’s networks using fNIRS data acquired from healthy subjects performing a continuous finger-tapping task. Using this method we show the directed connectivity patterns among cortical motor regions involved in the task and their significant variations in the strength of information flow exchanges. Intra and inter-hemispheric connections during the motor task with their temporal evolution are also provided. Characterisation of the …
Effect of undersized drilling on the stability of immediate tapered implants in the anterior maxillary sector. A randomized clinical trial.
2020
Background To evaluate the effect of undersized drilling on the primary and secondary stability of immediate implants placed in the anterior maxilla. Material and Methods A comparative randomized clinical trial was carried out in 30 healthy adults. Thirty tapered implants, 16 involving conventional drilling and 14 undersized drilling, were placed immediately after anterior maxillary tooth removal. Insertion torque and implant stability assessed by resonance frequency analysis (RFA) were evaluated at three different timepoints: at implant placement and 6 and 12 weeks post-implantation. The results were compared using parametric statistical tests. Results All implants showed adequate stabilit…
The location of the tibial accelerometer does influence impact acceleration parameters during running
2016
Tibial accelerations have been associated with a number of running injuries. However, studies attaching the tibial accelerometer on the proximal section are as numerous as those attaching the accelerometer on the distal section. This study aimed to investigate whether accelerometer location influences acceleration parameters commonly reported in running literature. To fulfil this purpose, 30 athletes ran at 2.22, 2.78 and 3.33 m · s–1 with three accelerometers attached with double-sided tape and tightened to the participants’ tolerance on the forehead, the proximal section of the tibia and the distal section of the tibia. Time-domain (peak acceleration, shock attenuation) and frequency-doma…
Comparison of implant primary stability between maxillary edentulous ridges receiving intramembranous origin block grafts
2012
Purpose: The purposes of the present study were: to compare the resonance frequency analysis (RFA) values of implant placed in either ramus or calvaria block grafts; and to determine if implant diameter influences RFA implant stability quotient (ISQ) value. Material and Methods: This was a retrospective study that included 16 consecutives healthy patients treated with autogenous onlay block grafts for horizontal bone reconstruction in maxilla. Ten ramus and ten calvaria block graft treated patients were selected and compared. Results: Totally, 59 implants were placed, 35 (59.3%) were placed on the calvaria bone grafts and the remaining 24 (40.7%) were on the ramus bone graft. Of all the imp…
Time and frequency analysis of the static balance in young adults with Down syndrome
2010
The main objective of this study is to understand the differences in equilibrium control between normal subjects and those with Down syndrome. A total of 54 subjects participated voluntarily, divided into control group and Down syndrome group. The equilibrium of the subjects was tested under two conditions: bipedal support with eyes open and closed. The signals were analyzed in a time and frequency domain. The statistical parameters selected (i.e., RMS distance, mean velocity, mean frequency and sway area) to analyze the behavior of the center of pressures (CoP) are calculated employing the result of the combination of the time series data in both directions (i.e. resultant distance). In or…
Effect of implant macro-design on primary stability: A prospective clinical study
2016
Background Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Methods A total of 47 implants divided in two groups: Test group (TI): 22 Tapered MIS® Seven implants; Control group (CI): 25 cylindrical Astra® Osseospeed implants. All implants were inserted following the manufacturers’ standard protocols. Implant primary stability was measured at the moment of implant placement by…
Phase information of time-frequency transforms as a key feature for classification of atrial fibrillation episodes
2015
[EN] Patients suffering from atrial fibrillation can be classified into different subtypes, according to the temporal pattern of the arrhythmia and its recurrence. Nowadays, clinicians cannot differentiate a priori between the different subtypes, and patient classification is done afterwards, when its clinical course is available. In this paper we present a comparison of classification performances when differentiating paroxysmal and persistent atrial fibrillation episodes by means of support vector machines. We analyze short surface electrocardiogram recordings by extracting modulus and phase features from several time-frequency transforms: short-time Fourier transform, Wigner-Ville, Choi-…
Resonance frequency analysis after the placement of 133 dental implants
2006
Introducción: La estabilidad primaria del implante dental está relacionada con el hueso que se encuentra en contacto con él y se puede medir mediante el análisis de frecuencia de resonancia. Material y métodos: En 133 implantes (62 en maxilar y 71 en mandíbula) se midió la frecuencia de resonancia y la fuerza de inserción para conocer la estabilidad de los implantes el día de la cirugía, y estudiar su relación con distintas variables. Resultados: El cociente de estabilidad del implante obtenido el día de la cirugía fue de 62’1 y el de la fuerza de inserción fue de 35’7 Nw. La fuerza de inserción fue proporcional al análisis de la frecuencia de resonancia, a mayor fuerza de inserción mayor c…